制造商:: -
Overview MSM-TPCVF is a multi in one gas sensor module, which can measure multiple gas indicators at the same time. The sensor module is equipped with laser particle sensor, infrared non spectroscopic carbon dioxide sensor, electrochemical formald...
Digital humidity & temperature sensor — specification summary
Date 2021-7-15
| Establishment | Audit | Approve | |
|---|---|---|---|
| 王艺言 | 吴岩富 | 陈飞 | |
| 2021-7-15 | 2021-7-15 | 2021-7-15 |

⚫ The laser scattering principle measures the concentration of particulate matter
⚫ Measurement of formaldehyde and TVOC by electrochemical and semiconductor principles
⚫ Measurement of carbon dioxide by infrared non-spectral principle
⚫ Internal integrated temperature and humidity detection chip
⚫ Highly integrated and convenient for user design
MSM-TPCVF is a multi in one gas sensor module, which can measure multiple gas indicators at the
same time. The sensor module is equipped with laser particle sensor, infrared non spectroscopic
carbon dioxide sensor, electrochemical formaldehyde sensor and semiconductor TVOC sensor, which
are respectively used to obtain particle concentration, carbon dioxide, formaldehyde and TVOC
concentration. The sensor module also contains a temperature and humidity sensor chip. Various
parameters will be uniformly output in the form of digital interface. By optimizing the sensor layout
structure, the sensor module not only ensures that the size of the sensor module is small enough, but
also ensures the sensitivity of each sensor.
Date 2021-7-15
Table 1-6
Table 1 Technical index of particulate matter concentration
Parameter Index Unit
Particulate matter measurement range 0.3~1.0 ; 1.0~2.5 ; 2.5~10 μm
Particulate count efficiency 50%@0.3 μm
Effective range of particulate mass concentration (PM2.5 standard value)
Maximum range of particulate mass concentration (PM2.5 standard value) 1
≥1000 μg/m³
Resolution of particulate matter mass concentration 1 μg/m³
Consistency of particulate matter mass concentration (PM2.5 standard value) 2
±10%@100~500 μg/m³
±10 μg/m³@0~100 μg/m³
Table 2 HCHO Concentration technical index
Detection accuracy ±0.05 mg/m³ or ±13% maximization
Table3 TVOC Concentration technical index
Effective range
Resolution
Table4 CO2 Concentration technical index
Table 5 Technical indexes of temperature and humidity
Temperature measuring
range -10~+60 ℃
Temperature measurement
resolution 0.1 ℃
Humidity measuring range 0~99 %
Humidity measurement
resolution 0.1 %
Table 6 Basic technical index
Operating temperature
Operating humidity range 0~99%
Table 2 Interface diagram
resistance)
Installation precautions
a) When applied to fresh air purifier products, the sensor should not be
directly placed in the air duct of the purifier as far as possible. If it
cannot be avoided, an independent structural space should be set
up separately, and the sensor should be placed in it to isolate it from
the air duct of the purifier. If it is unavoidable, please try to place the
b) When applied to fixed detection equipment, the sensor position shall be more
than 20cm above the ground. Otherwise it can be polluted by large dust particles or even flocs near the ground, causing the fan to be wound and stop rotating.
c) When the sensor is applied to outdoor fixed equipment, the
protection against sandstorms, rain and snow, willow catkins, etc.
shall be completed by the equipment user.
d) The sensor is an integral element, and users should not disassemble
it, including the metal shielding shell, to prevent irreversible damage.
Other precautions
a) The sensor module data ensures the consistency between the
factory individuals, and does not take the third-party testing
instrument or data as the comparison standard. If the user wants the
final measurement results to be consistent with a third-party testing
equipment, the user can carry out data fitting according to the actual
collected results.
b) This sensor is suitable for ordinary indoor environment. If the device
is used in the following environments, protective measures should
be applied to the sensor. Otherwise, data consistency may be
decreased due to excessive dust, oil, or water accumulation :
⚫ PM2.5 annual dust concentration is greater than 300 MCG/m3 for more than 50% of the time, or greater than 500 MCG/m3 for more than 20% of the time, such as smoking rooms
⚫ Fume environment, such as kitchen
⚫ High water mist environment, such as hot springs, bathrooms
⚫ The local temperature is too high or the sunlight is direct
⚫ outdoors
The last two bytes are the 16bit check code, which is the sum of the first five bytes
3 0x26 Length code low 8 bits, length code = data segment (n) + check byte (2)
4 The value of PM1.0 (standard particulate matter CF=1) is 8 digits higher
5 PM1.0 (standard particulate CF=1) is 8 digits lower,
The unit is ug/m³
6 PM2.5 (standard particulate matter CF=1) was 8 digits higher
7 PM2.5 (standard particulate matter CF=1) is 8 digits lower, The unit is ug/m³
8 The value of PM10 (standard particulate matter CF=1) is 8 digits higher
9 The value of PM10 (standard particulate CF=1) is 8 digits lower, in ug/m³
11 PM1.0 (atmospheric environment) value is 8 digits lower, ug/m³
12 PM2.5 (atmospheric environment) is 8 digits higher
13 PM2.5 (atmospheric environment) is 8 digits lower (ug/m³)
The value of PM10 (atmospheric environment) is 8 digits higher
The value of PM10 (atmospheric environment) is 8 digits lower, in ug/m³
The number of particles over 0.3 micron (0.1 liters) was eight higher
The number of particles larger than 0.3 micron (0.1 liters) was 8 lower
The number of particles larger than 0.5 micron (0.1 liter) was 8 higher
The number of particles larger than 0.5 micron (0.1 liters) was 8 lower
The number of particles over 1.0 micron (0.1 liter) was 8 higher
The number of particles larger than 1.0 micron (0.1 liters) was 8 lower
The number of particles over 2.5 microns (0.1 liters) was eight higher
The number of particles larger than 2.5 microns (0.1 liters) was 8 lower
The number of particles over 5.0 microns (0.1 liters) was 8 higher
The number of particles larger than 5.0 microns (0.1 liters) was 8 lower
The number of particles over 10.0 microns (0.1 liters) was 8 higher
The number of particles over 10.0 microns (0.1 liters) was 8 lower
28 The TVOC value is 8 bits higher
The TVOC value is 8 digits lower (unit PPM)
Note: Final value = 16-digit hexadecimal number converted to adecimal number /100
30 The TVOC value is 8 bits higher
The TVOC value is 8 digits lower, in mg/m³ Note: Final value = 16-digit hexadecimal number
converted to adecimal number /100
32 The HCHO value is 8 bits higher
The HCHO value is 8 digits lower (mg/m3) Note: Final value = 16-digit hexadecimal number converted to adecimal number /100
34 The CO2 value is 8 digits higher
35 The CO2 value is 8 digits lower (unit PPM)
36 The temperature value is 8 bits higher
The temperature value is 8 digits lower. Note: Final value = 16-digit hexadecimal number converted to adecimal number /10
38 The humidity value is 8 digits higher
The humidity value is 8 digits lower. Note: Final value = 16-digit hexadecimal number converted to adecimal number /10
40 The check word is 8 bits high
41 Check word lower 8 bits, 16bit check word = Sum of all bytes before the check word itself
concentration value obtained by density conversion of industrial metal
particulate matter as equivalent particle, which is suitable for industrial
production workshops and other environments; The mass concentration value
of atmospheric particulate matter is converted from the main pollutants in the
air as equivalent particles, which is suitable for ordinary indoor and outdoor
| Parameter | Index | Unit |
|---|---|---|
| Effective range | 0-1 | mg/m³ |
| Maximum range | 1.3 | mg/m³ |
| Resolution | 0.01 | mg/m³ |
| Parameter | Index | Unit |
|---|---|---|
| 0-65 | ppm |
| Parameter | Index | Unit | |
|---|---|---|---|
| Effective range | 0~10000 | ppm | |
| Maximum range | 20000 | ppm | |
| Resolution | 1 | ppm | |
| maximum error | ± ( 50ppm+3% | ) |
| Parameter | Index | Unit | |
|---|---|---|---|
| Single response time | 3 | Second | |
| Integrated response time | ≤30 | Second | |
| Dc supply voltage | Typ:5.0 Min:4.8 Max: 5.2 | V | |
| Average working current | ≤200 | mA | |
| Data interface level | L <0.8 @3.3 H >2.7@3.3 | V |
| Storage temperature range | -40~+80 | ℃ | |
|---|---|---|---|
| Mean time to failure | ≥3 | Years | |
| Size | 80*50*18 | mm |
| Pin number | Function label | Description | ||
|---|---|---|---|---|
| PIN1 | VCC | Power positive | ( +5V ) |
| 7. Product appearance dimensions | : | |
|---|---|---|
| (Unit: | mm ) | |
| weight | : 50g |
| Byte0 | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 |
|---|---|---|---|---|---|---|
| AC | 01 | 3B | ||||
| 42 | 4D | 00 | 00 |
| Byte | Value | Description | ||
|---|---|---|---|---|
| 0 | 0x42 | Feature byte | 1 | |
| 1 | 0x4D | Feature byte | 2 | |
| 2 | 0x00 | Length code height | 8-bit |